Coleman Furnace 445349 CTG B 0409 User Manual

445349-CTG-B-0409  
DESCRIPTION  
These compact units employ induced combustion, reliable hot  
surface ignition and high heat transferaluminized tubular heat  
exchangers. The units are factory shipped for installation in  
upflow or horizontal applications and may be converted for  
downflow applications.  
These furnaces are designed for residential installation in a  
basement, closet, alcove, attic, recreation room or garage and  
are also ideal for commercial applications. All units are factory  
assembled, wired and tested to assure safe dependable and  
economical installation and operation.  
TECHNICAL GUIDE  
GAS-FIRED RESIDENTIAL  
SINGLE STAGE MULTI-POSITION  
GAS FURNACES  
These units are Category I listed and may be common vented  
with another gas appliance as allowed by the National Fuel Gas  
Code.  
STANDARD &Low NOx MODELS  
FEATURES  
MODELS: TM8X / TMLX  
NATURAL GAS  
60 - 120 MBH INPUT  
Easily applied in upflow, horizontal left or right, or downflow  
installation with minimal conversion necessary.  
Compact, easy to install, ideal height 33" tall cabinet.  
Blower-off delay for cooling SEER improvement.  
Easy access to controls to connect power/control wiring.  
Built-in, high level self diagnostics with fault code displays  
standard on integrated control module for reliable operation.  
Low unit amp requirement for easy replacement application.  
All models are convertable to use propane (LP) gas.  
Electronic Hot Surface Ignition saves fuel cost with increased  
dependability and reliability.  
100% shut off main gas valve for extra safety.  
5 speed direct drive, X13 style high efficiency DC motor.  
24V, 40 VA control transformer and blower relay supplied for  
add-on cooling.  
Hi-tech tubular aluminized steel primary heat exchanger.  
Timed on, adjustable off blower capability for maximum  
comfort.  
Blower door safety switch.  
Solid removable bottom panel allows easy conversion.  
Low NOx models have been designed to meet specific code  
requirements.  
Airflow leakage less than 1% of total airflow at ductblaster  
conditions.  
EFFICIENCY  
RATING  
CERTIFIED  
No knockouts to deal with, making installation easier.  
Movable duct connector flanges for application flexibility.  
Quiet inducer operation.  
ISO 9001  
Certified Quality  
Management System  
Inducer rotates for easy conversion of venting options.  
Fully supported blower assembly for easy access and  
removal of blower.  
External air filters used for maximum flexibility in meeting  
customers IAQ needs.  
Due to continuous product improvement, specifications  
are subject to change without notice.  
Additional rating information can be found at  
Venting applications - may be installed as a common vent  
with other gas-fired appliances or use a masonry chimney.  
1/4 turn knobs provided for easy door removal.  
High-efficiency blower motor for lower electrical power usage  
and improved A/C SEER ratings.  
WARRANTY  
Insulated blower compartment for thermal and acoustic  
performance.  
20-year limited warranty on the heat exchanger.  
10-year heat exchanger warranty on commercial applications.  
Standard 5-year limited Parts warranty.  
Extended 10-year limited parts warranty when product is regis-  
tered online within 90 days of purchase for replacement or clos-  
ing for new home construction.  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
 
445349-CTG-B-0409  
Recommended Filter Sizes  
CFM  
Cabinet  
Size  
Side  
(in)  
Bottom  
(in)  
1200  
1200  
1600  
2000  
A
B
C
C
16 x 25  
16 x 25  
14 x 25  
16 x 25  
20 x 25  
20 x 25  
16 x 25  
(2) 16 x 25  
NOTES:  
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity fil-  
ters.  
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the  
bottom or one return with a transition to allow use of a 20x25 filter.  
Unit Clearances to Combustibles (All dimensions in inches, and all surfaces identified with the unit in an upflow  
configuration)  
Left  
Side  
Right  
Side  
Floor/  
Bottom  
Line  
Contact  
Application  
Upflow  
Top  
Front  
Rear  
Flue  
Closet  
Alcove  
Attic  
1
1
1
6
3
6
0
0
0
0
0
0
3
0
3
6
1
6
Combustible  
Combustible  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
Upflow B-Vent  
Downflow  
11  
11  
Downflow B-Vent  
Horizontal  
1
1
1
3
6
3
0
0
0
0
0
0
0
3
0
1
6
1
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Yes2  
Yes2  
Combustible  
Combustible  
Horizontal B-Vent  
1. Special floor base or air conditioning coil required for use on combustible floor.  
2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and build-  
ing joists, studs or framing.  
EAC TRANSITION KITS -  
ACCESSORIES  
For installation of EAC accessories with these furnaces to  
provide easy transition of return airflow through the EAC to  
get the proper sealing and reduced airflow leakage.  
PROPANE (LP) CONVERSION KIT -  
1NP0347 - All Models  
This accessory conversion kit may be used to convert natural  
gas units for propane (LP) operation.  
1TK1001 - For all models using side return  
1TK1014 - For 14-1/2” cabinets using bottom return  
1TK1017 - For 17-1/2” cabinets using bottom return  
1TK1021 - For 21” cabinets using bottom return  
MASONRY CHIMNEY KITS -  
SIDE RETURN FILTER RACKS -  
1SR0200 - All Models  
1SR0302 - All Models  
BOTTOM RETURN FILTER RACKS -  
1CK0603  
1BR0514 or 1BR0614 - For 14-1/2” cabinets  
1BR0517 or 1BR0617 - For 17-1/2” cabinets  
1BR0521 or 1BR0621 - For 21” cabinets  
1CK0604  
For installations where these furnaces are vented using  
existing or new lined masonry chimneys.  
1BR05xx series are galvanized steel filter racks. 1BR06xx  
are pre-painted steel filter racks to match the appearance of  
the furnace cabinet.  
HIGH ALTITUDE PRESSURE SWITCHES -  
For installation where the altitude is less than 5,000 feet it is  
not required that the pressure switch be changed. For alti-  
tudes above 5,000 feet, see kits below.  
1PS3301  
COMBUSTIBLE FLOOR BASE KIT -  
For installation of these furnaces in downflow applications  
directly onto combustible flooring material. These kits are  
required to prevent potential overheating situations. These  
kits are also required in any applications where the furnace in  
installed in a downflow configuration without an evaporator  
coil, where the combustible floor base kit provides access for  
combustible airflow.  
1CB0514 - For 14-1/2” cabinets  
1CB0517 - For 17-1/2” cabinets  
1CB0521 - For 21” cabinets  
1PS3302  
ROOM THERMOSTATS - A wide selection of compatible  
thermosets are available to provide optimum performance  
and features for any installation.  
1H/1C, manual change-over electronic non-programmable  
thermostat.  
1H/1C, auto/manual changeover, electronic programmable,  
deluxe 7-day, thermostat.  
1H/1C, auto/manual changeover, electronic programmable.  
* For the most current accessory information, refer to the  
price book or consult factory.  
Johnson Controls Unitary Products  
3
 
Blower Performance CFM - Any Position (without filter)  
Airflow Data (SCFM)  
Models  
Speed  
Ext. Static Pressure (in. H2O)  
0.1  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
1100  
920  
0.8  
1070  
860  
0.9  
1020  
810  
1.0  
970  
780  
560  
360  
NA  
High  
Medium High  
Medium  
Medium Low  
Low  
1350  
1180  
1010  
940  
1320  
1140  
960  
1280  
1100  
910  
1240  
1050  
860  
1200  
1010  
800  
1150  
970  
760  
720  
640  
620  
TM(8,L)X060A12MP11  
820  
730  
680  
590  
560  
500  
460  
400  
910  
700  
540  
430  
380  
NA  
NA  
NA  
NA  
High  
1460  
1190  
1010  
980  
1440  
1160  
970  
1410  
1130  
940  
1240  
1090  
890  
1210  
1050  
840  
1170  
1010  
800  
1130  
960  
1090  
910  
1050  
870  
1000  
770  
570  
360  
NA  
Medium High  
Medium  
Medium Low  
Low  
750  
700  
610  
TM(8,L)X080B12MP11  
TM(8,L)X080C16MP11  
TM(8,L)X100C16MP11  
TM(8,L)X100C20MP11  
860  
770  
730  
660  
620  
490  
460  
400  
910  
800  
590  
430  
400  
NA  
NA  
NA  
NA  
High  
1780  
1620  
1440  
1250  
1090  
1750  
1580  
1420  
1210  
1020  
2190  
1830  
1580  
1410  
1150  
2210  
1830  
1610  
1400  
1160  
1730  
1570  
1400  
1200  
960  
1690  
1530  
1350  
1140  
700  
1650  
1480  
1290  
1090  
580  
1590  
1430  
1250  
1030  
440  
1540  
1390  
1200  
970  
1490  
1340  
1140  
910  
1440  
1280  
1090  
850  
1400  
1230  
1030  
720  
1340  
1100  
930  
680  
NA  
Medium High  
Medium  
Medium Low  
Low  
400  
NA  
NA  
NA  
High  
1700  
1540  
1380  
1170  
890  
1660  
1490  
1330  
1110  
660  
1610  
1440  
1290  
1060  
560  
1560  
1400  
1230  
1010  
420  
1510  
1350  
1180  
950  
1460  
1310  
1130  
880  
1420  
1260  
1080  
830  
1370  
1150  
990  
1310  
1110  
910  
670  
NA  
Medium High  
Medium  
Medium Low  
Low  
710  
390  
NA  
NA  
NA  
High  
2160  
1790  
1530  
1360  
1020  
2160  
1800  
1560  
1340  
1020  
2110  
1740  
1480  
1310  
850  
2060  
1700  
1430  
1250  
770  
2020  
1650  
1380  
1190  
680  
1980  
1600  
1330  
1130  
560  
1930  
1520  
1280  
1070  
510  
1890  
1490  
1230  
1010  
NA  
1810  
1430  
1160  
900  
1710  
1380  
1060  
830  
NA  
Medium High  
Medium  
Medium Low  
Low  
NA  
High  
2120  
1750  
1510  
1290  
850  
2070  
1710  
1470  
1230  
770  
2030  
1650  
1410  
1160  
680  
1980  
1610  
1360  
1100  
620  
1950  
1560  
1300  
1040  
510  
1900  
1520  
1250  
980  
1840  
1410  
1150  
910  
1720  
1350  
1060  
830  
NA  
Medium High  
Medium  
Medium Low  
Low  
TM(8,L)X120C20MP11  
NA  
NA  
NOTES:  
1. Airflow expressed in standard cubic feet per minute (CFM).  
2. Motor voltage at 115 V.  
Subject to change without notice. Printed in U.S.A.  
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.  
445349-CTG-B-0409  
Supersedes: 445349-CTG-A-0109  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  
 

Coleman Stove 425G User Manual
Crate Amplifiers Musical Instrument Amplifier GT3500H User Manual
Cuisinart Blender CBT 1000 User Manual
Duracell Battery Charger MN1400 User Manual
Edimax Technology Network Card EW 7206PDg User Manual
Ericsson Telephone LBI 39169 User Manual
Extron electronic Speaker SI 26CT User Manual
Ford Automobile 2007 Fusion User Manual
Frigidaire Air Conditioner FRP12PTT2R User Manual
Furman Sound Surge Protector PST 10D User Manual